Most of our features and services are available only to members, so we encourage you to login or register a new account. Registration is free, fast and simple. You only need to provide a valid email. Being a member you'll gain access to all member forums and features, post a message to ask question or provide answer, and share or find resources related to mobile phones, tablets, computers, game consoles, and multimedia.

All that and more, so what are you waiting for, click the register button and join us now! Ito ang website na ginawa ng pinoy para sa pinoy!

Certified Aircon Tech here..lets talk about Ref and Airconditioning...

jhon357

The Fanatic
Advanced Member
Messages
468
Reaction score
1
Points
28
Sa mga may katanungan dyan about sa Refrigeration and Airconditioning..tanong niyo lang at sasagutin ko yan..

Im TESDA DOMRAC NCII Certified and currently working in airconditioning industry..lahat ng aircon technician diyan your open to give advice din..


View attachment 182305
 

Attachments

  • theory.gif
    theory.gif
    15.5 KB · Views: 252
Last edited:
Sir may manual ba kau regarding sa aircon and ref coz ang field ko kasi is electrical gusto ko matutunan tlga ang ref and aircon although may knowledge naman ako kaso basic lang tlga
 
Sir may manual ba kau regarding sa aircon and ref coz ang field ko kasi is electrical gusto ko matutunan tlga ang ref and aircon although may knowledge naman ako kaso basic lang tlga

wala po boss eh..Ive suggest n mag aral k nlng po sa TESDA ng RAC Servicing para cgurado na matututo ka ng theory and actual...suggest ko lang po..
 
Sir,
Tanong ko lang pano i compute kung ilang horse power ang kelangan sa isang room?
 
Need ko rin info about standing type kung ilan karaniwan rating niya base sa nameplate. Pinakamaliit at malaki sa mga commercial lang naman.
 
pasali nga dito gusto ko kumuha ng rac nc2 electrician din ako
 
Sir,
Wala pa po kayo sagot sa 1st question ko, pero meron uli ako 2nd question: pano hanapin yung Common, Starting & running sa terminal ng compressor? Sana masagot nyo po.... Salamat
 
Sir,
Tanong ko lang pano i compute kung ilang horse power ang kelangan sa isang room?

Per 15 sqm=1hp..pero BTU or Total heatload din ang binabasehan pra malaman ang tamang capacity ng ACU sa isang area..

Sir,
Wala pa po kayo sagot sa 1st question ko, pero meron uli ako 2nd question: pano hanapin yung Common, Starting & running sa terminal ng compressor? Sana masagot nyo po.... Salamat

Pra mahanap nag terminals ng compressor..hanapin mo muna ang common...diba may tatlong terminals ang compressor yung like pa triangle use multi tester para malaman mo ang resistance ng bawat terminal.."common highest resistance reading starting 2nd to the highest and lowest reading ng resistance ang running.."

pasali nga dito gusto ko kumuha ng rac nc2 electrician din ako


nice ayos yan.. :thumbsup:
 
Last edited:
sir about sa thesis namin.

dalawang aircon, isa backup isa running. tapos ang trigger namin ay temperature sensor para maiswitch between running saka backup.
condition lang ng pag switch ng aircon pag tumaas temperature ng room.(running to backup) anu ba maganda gamitin switching para sa aircon pwera sa relay? thanks po.
 
sir pa :help: naman po pag hndi lumalamig ang evaporator ng ref, nagpapawis lang anu po kaya posibleng sira? umaandar naman ang compressor. baka puwede nyo akong matulungan. thanks po sir.
 
sir about sa thesis namin.

dalawang aircon, isa backup isa running. tapos ang trigger namin ay temperature sensor para maiswitch between running saka backup.
condition lang ng pag switch ng aircon pag tumaas temperature ng room.(running to backup) anu ba maganda gamitin switching para sa aircon pwera sa relay? thanks po.

anong course mo boss?..bago ko sagutin...

sir pa :help: naman po pag hndi lumalamig ang evaporator ng ref, nagpapawis lang anu po kaya posibleng sira? umaandar naman ang compressor. baka puwede nyo akong matulungan. thanks po sir.


Possible boss..may leak ang evaporator niya..anong type b ung evaporator niyan shell type ba ung prang bakat yung linya nung piping niya ng freon.?..system reprocess nyan boss..search mo nlng kay google anong tools at panu gawin ang system reprocess.. :thumbsup:
 
Last edited:
yung evaporator nya po yung walang mga tube parang embedded na sa plate nya, shell type po ba tawag dun? kakalasin ko po ba yung evaporator nya o i-flushing na yung buong system? yung condenser nya po pala nakatago sa body nya parang yun na din ang heater. di ko na po maaninag yung tatak at natangal na din. tesda NC-1 din po ako master pero limot ko na kc ibang posisyon ko sa napasukan kong kumpanya. :what: sayang yung pinag-aralan ko, hehe..:upset:
 
Sir,
Wala pa po kayo sagot sa 1st question ko, pero meron uli ako 2nd question: pano hanapin yung Common, Starting & running sa terminal ng compressor? Sana masagot nyo po.... Salamat
compressor terminal tagging... any fb is highly accepted
 

Attachments

  • Screenshot .jpg
    Screenshot .jpg
    145.2 KB · Views: 84
papsmay ref ako na 2 door condura hindi ko nagamit ng 1 year ngayon ayaw ng gumana walang ilaw walang tunog kumbaga eh deadset na. ano kaya ang naging problema nito. gumagana naman ng pinatay namin to.any advice boss.
 
Sir ilan ang btu equivalent kung 1 tonnage ang usapan?
sir
BTU is a unit of energy and,
TONS is a unit of capacity
lagyan nalang natin ng per hour yong btu mo para maging capacit
12000 BTU/HOUR =1 TON(refrigeration)


papsmay ref ako na 2 door condura hindi ko nagamit ng 1 year ngayon ayaw ng gumana walang ilaw walang tunog kumbaga eh deadset na. ano kaya ang naging problema nito. gumagana naman ng pinatay namin to.any advice boss.

sir anu bah ref mo? no-frost bah? marunong kaba gumamit ng ohmmeter?
 
yung evaporator nya po yung walang mga tube parang embedded na sa plate nya, shell type po ba tawag dun? kakalasin ko po ba yung evaporator nya o i-flushing na yung buong system? yung condenser nya po pala nakatago sa body nya parang yun na din ang heater. di ko na po maaninag yung tatak at natangal na din. tesda NC-1 din po ako master pero limot ko na kc ibang posisyon ko sa napasukan kong kumpanya. :what: sayang yung pinag-aralan ko, hehe..:upset:

hirap paliwanag boss..mahaba kasi proseso..search mo nlng po kay google/youtube pano yung system reprocess.. :yes: :yes:


Sir ilan ang btu equivalent kung 1 tonnage ang usapan?

tons/hp=capacity ng unit un...iba p yung heatload..ang heatload un ung total n nilalabas ng init ng area na iinistallan mo ng ACU..wala kasi survey form ko sa office eh..bumabase kami sa total heatload ng area..para malaman nmin kung tama b yung capacity ng ACU na ikakabit nmin dun sa area..for example 1HP=9000 BTU..ganun hindi lang kami bumabase sa lawak nung area ng pagkakabitan ng ACU..

papsmay ref ako na 2 door condura hindi ko nagamit ng 1 year ngayon ayaw ng gumana walang ilaw walang tunog kumbaga eh deadset na. ano kaya ang naging problema nito. gumagana naman ng pinatay namin to.any advice boss.

gamit ka multi tester..check mo po yung wiring...mas maganda kung marunong ka magbasa ng schematic diagram..pra malaman mo kung anong piyesa ng ref mo ang may problema..mahaba kasi proseso sa pag check nung wiring nyan..para mapaandar ang ref..


BTW c Jhon po ito...yunng main account ko..nirerecover ko pa..nakalimutan ko email eh..
 
Last edited:
thanks sir jhon.. mag-update na lang ako pag ok na.. :salute:


@vboi
sir, tama c sir jhon, check mo po muna power cord mo baka may ngatngat ni pareng ben. continuity test po muna sa circuit nya.
 
Last edited: