Most of our features and services are available only to members, so we encourage you to login or register a new account. Registration is free, fast and simple. You only need to provide a valid email. Being a member you'll gain access to all member forums and features, post a message to ask question or provide answer, and share or find resources related to mobile phones, tablets, computers, game consoles, and multimedia.

All that and more, so what are you waiting for, click the register button and join us now! Ito ang website na ginawa ng pinoy para sa pinoy!

How to make your own home solar. With Pictures + solar book

sir wamiruk hindi poh ba itatakeover ng battery ng ups ung timer kung sakali. Iniisip ko lng poh kce bka dhil lowbat ung battery kya pinapatay ng ups yng output supply nia. Hnd ba sa software ng ups kya nia pinapatay ng yung outpot na power ac. Prang magiging inverter yng ups kung sakali?

- - - Updated - - -

yung timer po ng UPS sa hardware level po lalo na yung APC. pero nasubukan ko po dati ibang mumurahin na brand... panay nga lang beep ng UPS.
 
Sir tristan hnd nio poh ba nsubukan n gwin ung charge controller na gwin supply doon sa ups nio? Iniisip ko lng poh kce bka hnd na kailangan bumili ng inverter kung gagana?
nabasa ko kasi na mas compatible ang desktop computer sa pure sine wave inverter kung gagamitin ng matagal... ang APC 550VA UPS ko ay ginagamit lamang para mag-bigay ng power habang tina-transfer ko (manual transfer switch) sa solar powered pure sine wave inverter... so pag-pasok ng kuryente galing sa pure sine wave inverter, standby na ulit si small UPS.... at sa solar powered pure sine wave inverter na galing ang kuryente... linagyan ko ng battery low voltage alarm para kapag low-batt na transfer ko ulit sa AC power... so, every manual transfer lang gagana si small UPS.
 
nabasa ko kasi na mas compatible ang desktop computer sa pure sine wave inverter kung gagamitin ng matagal... ang APC 550VA UPS ko ay ginagamit lamang para mag-bigay ng power habang tina-transfer ko (manual transfer switch) sa solar powered pure sine wave inverter... so pag-pasok ng kuryente galing sa pure sine wave inverter, standby na ulit si small UPS.... at sa solar powered pure sine wave inverter na galing ang kuryente... linagyan ko ng battery low voltage alarm para kapag low-batt na transfer ko ulit sa AC power... so, every manual transfer lang gagana si small UPS.

salamat sa info sir tristan. Atleast medyu alam ko na, na hindi pla tlaga pwedeng mging inverter yng ups. as back-up lng pla tlga. More power dito sa thread na to. medyu nagbaback read pa ako dito, pra lumalim yng idea ko about solar power. Para in the future na balak kong magassembly ng solar eh medyu alam ko...

- - - Updated - - -

sir wamiruk hindi poh ba itatakeover ng battery ng ups ung timer kung sakali. Iniisip ko lng poh kce bka dhil lowbat ung battery kya pinapatay ng ups yng output supply nia. Hnd ba sa software ng ups kya nia pinapatay ng yung outpot na power ac. Prang magiging inverter yng ups kung sakali?

- - - Updated - - -

yung timer po ng UPS sa hardware level po lalo na yung APC. pero nasubukan ko po dati ibang mumurahin na brand... panay nga lang beep ng UPS.

Salamat sa info sir wamiruk. Atleast ngyn alam ko na tlga na hnd tlga sa software nagdidipende yng ups.. Sa tingin mo ba pwedeng ma bypass yng timer?
 
salamat sa info sir tristan. Atleast medyu alam ko na, na hindi pla tlaga pwedeng mging inverter yng ups. as back-up lng pla tlga. More power dito sa thread na to. medyu nagbaback read pa ako dito, pra lumalim yng idea ko about solar power. Para in the future na balak kong magassembly ng solar eh medyu alam ko...
Ganito ang gusto mong i-setup

https://img.clasf.co.za/2015/12/20/UPS-LONG-RUN-TIME-PURE-SINE-WAVE-800VA-1-5-KVA-20151220134912.jpg

UPS. LONG RUN TIME. PURE SINE WAVE - Our UPS provides simple, uninterrupted power, protecting computers and other sensitive electronics from power surges and load shedding. Large capacity GEL batteries keep you working through power cuts. No need to shut down if the power goes off for a few hours. The Smart Power System can be used straight out of the box and does not require an electrician. Available in three sizes… SPS-500 800VA (500W) SPS-600 1KVA (600W) SPS-1000 1.5KVA (1000W) Simple operation - plugs into a standard wall socket (cable supplied). Fully automatic. Uninterrupted power (UPS). Long back up time. Professional all-in-one cabinet. Pure Sine Wave inverter. PWM Solar controller (on SPS 600 and 1000). 3 stage battery charger. Intelligent CPU control. Automatic Voltage Regulation. LCD Information display- battery charge, input/output voltage. Re-settable overload protection. Low battery/overload warning. 2 x Peak Surge capacity. Portable - on wheels. No exposed wiring. Lockable battery compartment. Fan cooling
 
Bali sir Tristan, Hindi po pla nakakaapekto sa isang Solar septup kung magkakaibang type yung battery po..

sample po eto, Pwede kaya iconnect tong 3 na ito.. ty po
Gel-type + Motolite + Lithium ion battery
 
Bali sir Tristan, Hindi po pla nakakaapekto sa isang Solar septup kung magkakaibang type yung battery po..

sample po eto, Pwede kaya iconnect tong 3 na ito.. ty po
Gel-type + Motolite + Lithium ion battery
hindi pwede kasi mapili si solar charge controller, kung gel type, gusto nya gel din ang partner, kung flooded, flooded din ang partner at pare-pareho sila ng edad o age... sa lithium naman, ibang klase ang charge controller, meron syang battery management system (bms) kasi sumasabog sya..
 
Last edited:
New Mobilarian here, and masaya ako na meron palang solarista group dito.

May first question here are:

Meron na ba gumagamit dito ng Smart BMS with Bluetooth? If meron na, saan nyo nabili and magkano? thank you and more solar power.
 
Hello ka MB. May tanong lang sana ako, salamat sa makasagot.

Exp.
If may 3 pcs 12Volts batteries po ako na 100AH (Ampere Hour)
if series 36 Volts 100AH . Tama ba?
If Parallel 12 Volts 300AH. Tama ba?

If series (between battery to battery ) anong size or guage na wire ang gagamitin ko. ? at bakit ?
If Parallel (between battery to battery ) anong size or guage na wire ang gagamitin ko. ? at bakit ?
depende ba sa load sa inverter kung ilang ampere ang kakainin nya?

anong gauge ang gagamitin ko dito? at bakit?
14-gauge wire: 15 amps
12-gauge wire: 20 amps
10-gauge wire: 30 amps
8-gauge wire: 40 amps
6-gauge wire: 55 amps
4-gauge wire: 70 amps
3-gauge wire: 85 amps
2-gauge wire: 95 amps

Maraming salamat po...
 
Last edited:
Salamat sa info sir wamiruk. Atleast ngyn alam ko na tlga na hnd tlga sa software nagdidipende yng ups.. Sa tingin mo ba pwedeng ma bypass yng timer?

madami kasi sir klase ng UPS iba iba din yung pagkakagawa merong magaling sa electronics na makakapag disable ng timer. nakaranas ako dati nakapag uwi kami ng UPS galing sa barko pero 110v. pina convert namin sa raon to 220v. Ang problema masyadong komplikado yung UPS kaya nilagyan nalang ng choke yung UPS para magamit sa 220v.

Hello ka MB. May tanong lang sana ako, salamat sa makasagot.

Exp.
If may 3 pcs 12Volts batteries po ako na 100AH (Ampere Hour)
if series 36 Volts 100AH . Tama ba?
If Parallel 12 Volts 300AH. Tama ba?

If series (between battery to battery ) anong size or guage na wire ang gagamitin ko. ? at bakit ?
If Parallel (between battery to battery ) anong size or guage na wire ang gagamitin ko. ? at bakit ?
depende ba sa load sa inverter kung ilang ampere ang kakainin nya?

anong gauge ang gagamitin ko dito? at bakit?
14-gauge wire: 15 amps
12-gauge wire: 20 amps
10-gauge wire: 30 amps
8-gauge wire: 40 amps
6-gauge wire: 55 amps
4-gauge wire: 70 amps
3-gauge wire: 85 amps
2-gauge wire: 95 amps

Maraming salamat po...


gaano ka laki consumption mo sir?
anong inverter gamit mo sir? kung mas mataas ang voltage mo sir mas less current ang dadaloy... mas maliit na wire ang pwedeng gamitin

example: inverter is 12v@1000w = kung sagad na 1000w ang load mo kakain ng 83.33amps
inverter is 36v@1000w = kung sagad na 1000w ang load mo kakain ng 27.78 amps
inverter is 48v@1000w = kung sagad na 1000w ang load mo kakain ng 20.83 amps

mahal ang wire sir
 
madami kasi sir klase ng UPS iba iba din yung pagkakagawa merong magaling sa electronics na makakapag disable ng timer. nakaranas ako dati nakapag uwi kami ng UPS galing sa barko pero 110v. pina convert namin sa raon to 220v. Ang problema masyadong komplikado yung UPS kaya nilagyan nalang ng choke yung UPS para magamit sa 220v.




gaano ka laki consumption mo sir?
anong inverter gamit mo sir? kung mas mataas ang voltage mo sir mas less current ang dadaloy... mas maliit na wire ang pwedeng gamitin

example: inverter is 12v@1000w = kung sagad na 1000w ang load mo kakain ng 83.33amps
inverter is 36v@1000w = kung sagad na 1000w ang load mo kakain ng 27.78 amps
inverter is 48v@1000w = kung sagad na 1000w ang load mo kakain ng 20.83 amps

mahal ang wire sir

salamat sa info. sir...dapat pala mataas voltahe ko para mababa amps...tnx
 
I cannot see properly, but it seems to me that the 2 first setups are ok... but the third one, kulang sa battery. Your 1000 watt inverter will consume all the battery... you don't need a so big inverter (500 watt is enough) but even with a 500-watt inverter kulang parin ang battery for a 300-watt pc! 300 watt = 25 Ah (meaning it consumes 25 amperes per hour... so if you use your pc let's say 4 hrs per day it will use 100 Ah already, not including the router + monitor + inverter!)
... And with a bigger bat you need more or bigger panels and bigger controller
Also for the 3 setups, you don't say how many hours per day you intend to run each appliance.
 
Last edited:
gud day po patulong naman po kung ilang AH na battery at ilang watts na solar panel sa set up po na ito

set up 1. 4 pcs na dc fans na 16 watts that will run for 12 hours
4 pcs na dc led bulb 9 watts that will run for 8 hours

set up 2. 2 pcs na dc fans na 16 watts that will run for 12 hours
 
gud day po patulong naman po kung ilang AH na battery at ilang watts na solar panel sa set up po na ito

set up 1. 4 pcs na dc fans na 16 watts that will run for 12 hours
4 pcs na dc led bulb 9 watts that will run for 8 hours

set up 2. 2 pcs na dc fans na 16 watts that will run for 12 hours
1. 400W panel 200AH battery
2. 200W panel 100AH battery or 160W panel 70AH battery
 
Thank you po sa reply. Ganun po ba yon na laging times 2 ng battery yung solar panel.
basing on personal experience, mas sigurado na mare-recharge ang 50% na kinuha mo sa loob ng isang araw na re-charging kapag ganyan ang ratio.
 
it will be a helpful thread in the future... bookmarked this one! thank you so much for your share...
 
Thank you po sa reply. Ganun po ba yon na laging times 2 ng battery yung solar panel.
gusto mong gumamit ng 4x16=64watts dc fans at 4x9=36watts dc led bulbs, total of 100watts dc... assuming na ginamit mo for 10hours = 1000 watt-hour lahat ang na-discharge mo sa battery ...ang tanong, paano mo ibabalik sa battery ang nagamit mo?

100AH x 12V = 1200watt-hour = 1000/1200= 83.33% depth of discharge ...so hindi pwede gamitin ang 100AH battery
200AH x 12V = 2400watt-hour = 1000/2400= 41.67% depth of discharge ... so dapat ay 200AH battery ang gamitin

so kung 100W panel ang gagamitin na pang charge = 1000watt-hr / 100W = 10hrs ang charging time, so kung makulimlim ang panahon, baka hindi ma-full charge
so kung 400W panel ang gagamitin na pang charge = 1000watt-hr / 400W = 2.5hrs lang ay naibalik mo na ang 1000 watt-hr na nagamit mo, at maski makulimlim ay sure ka na mafu-full charge ulit si battery.
 
Last edited: